Free from Relay, no signup. Sources checked November 16, 2026.

A visit record for residential central air conditioning. Use it for a spring cooling visit or routine maintenance, adapting the scope to the specific system.

For qualified HVAC professionals. Use the equipment manual for test methods and acceptable readings.

What to record

Identify the system

  • Record indoor and outdoor model/serial numbers, refrigerant and customer concerns
  • Identify the service procedure, operating mode and indoor/outdoor test conditions

Air path and drainage

  • Record filter size, condition and action taken
  • Document accessible indoor coil and blower condition; note cleaning completed
  • Inspect outdoor coil, fan and clearances; record debris removal or damage
  • Record condensate pan, drain and fitted overflow-control test results
  • Document visible duct and register restrictions and inaccessible areas

Electrical and cooling operation

  • Record qualified inspection of disconnect, wiring and terminations under the equipment procedure
  • Record voltage, motor current and fitted capacitor readings against equipment ratings
  • Document refrigerant-line condition and leak observations; record charge verification only when the procedure and conditions allow
  • Record airflow/static-pressure and supply/return temperature checks with measurement locations
  • Document thermostat response and the observed cooling cycle

Close the visit

  • Separate maintenance completed from repairs recommended
  • Record unresolved concerns, tests deferred and customer instructions

Measurements and test conditions

Record actual values, units, equipment identity and test conditions. Add the specified limit and its manual or design reference in the measurement note.

  • Supply and return air temperatures (°F or °C), locations and cooling mode
  • External static pressure (in. w.c. or Pa), test ports and blower setting
  • Supply voltage (V), identified motor current (A), capacitor value (µF) where fitted
  • Refrigerant readings only under the model-specific procedure; record units and conditions

Plan the scope

Plan cooling maintenance before heavy summer use. A calendar reminder does not determine filter service: condition, use and the equipment instructions do. If weather prevents a valid performance test, record the limitation and arrange a return test.

A field documentation example

If the drain was cleared but cooling performance could not be tested, record the drain work under Work performed. Leave the cooling item Not recorded, explain the conditions in its note and put the return test under Recommendations.

References and adaptation

For qualified HVAC professionals. Adapt to the equipment manual, approved scope and applicable requirements. These are original documentation aids, not manufacturer procedures, ACCA forms or compliance certificates. Use equipment-specific limits; no universal passing values are supplied.

  • ENERGY STAR: maintenance topics
  • Carrier: AC maintenance
  • ACCA: quality maintenance and installation standards

Other HVAC checklists

  • Furnace maintenance checklist
  • Heat pump maintenance checklist
  • Ductless mini-split maintenance checklist
  • HVAC installation and commissioning checklist

Questions

Can I print a blank checklist without creating a report?

Yes. Download blank checklist PDF gives you an uncompleted field worksheet with room for results, notes and readings. It requires no account or visit details.

Can I edit the checklist and export a customer report?

Yes. Open Record a visit to use the shared service report builder. New report uses this page's checklist. You can edit items, add notes, measurements and photos, and export from Preview after recording the visit date and at least one result or observation. Unanswered items stay Not recorded.

Does opening this page replace my saved reports?

No. Existing reports stay in the shared library on this browser. Choose New report to start this checklist. Download a backup to preserve your reports or move them to another device; this free tool does not sync with operational Relay jobs.

Does a completed checklist certify safety or code compliance?

No. It records the work and observations entered by its author. Equipment procedures, qualified testing and applicable requirements determine acceptance. No readings or passing limits are filled in automatically.

All HVAC resources

All free tools

Product

  • All features
  • AI Front Office
  • Business Phone
  • Website
  • Booking
  • Pipelines
  • Ask Relay and connected agents
  • Scheduling & dispatch
  • Mobile App
  • Pricebook
  • Inventory
  • Time tracking & timesheets
  • Estimates & proposals
  • Invoicing & payments
  • Customer management
  • Maintenance plans
  • Review requests
  • Customer campaigns
  • Reports & profitability

Compare

  • Relay vs Housecall Pro
  • Relay vs Jobber
  • Relay vs ServiceTitan
  • Relay vs Workiz
  • Relay vs FieldPulse

Industries

  • HVAC
  • Plumbing
  • Electrical
  • Garage door
  • Appliance repair

Legal

  • Privacy
  • Terms
  • SMS Policy
  • Account Deletion

Company

  • About
  • Guides
  • Free tools
  • Help center
  • Contact
  • Support
© 2026 Relay Ops, Inc.