Free heat pump maintenance checklist
Free from Relay, no signup. Sources checked November 16, 2026.
A residential air-source heat pump visit record covering both seasons. Use the ductless checklist for indoor-head detail; ground-source and hydronic systems need different procedures.
For qualified HVAC professionals. Use the equipment manual for test methods and acceptable readings.
What to record
System and airflow
- Record matched indoor/outdoor equipment, refrigerant, controls and customer concern
- Record filter, indoor coil and blower condition and service performed
- Document outdoor coil condition, clearances, mounting and drainage
- Record ducted airflow/static-pressure checks and visible duct restrictions
Refrigeration and electrical
- Document refrigerant-line condition and leak observations
- Record charge verification method, mode and conditions when permitted by the manufacturer
- Record electrical connections, voltage, motor current and applicable component checks
Heating and cooling modes
- Record heating and cooling tests actually performed, including temperature measurements
- Document reversing-valve response under the service procedure
- Record defrost verification method and result, or why it was deferred
- Document auxiliary/emergency heat staging where fitted
- Record dual-fuel changeover and control settings where applicable
- Document condensate and fitted overflow-control tests
Customer handover
- Record thermostat/control demonstration and any settings changed
- List unresolved issues, untested modes and a return-test plan
Measurements and test conditions
Record actual values, units, equipment identity and test conditions. Add the specified limit and its manual or design reference in the measurement note.
- Indoor/outdoor conditions and operating mode for each test
- Supply/return temperatures (°F or °C), plus airflow or static readings where applicable
- Voltage (V) and current (A) with the component or heat stage identified
- Refrigerant measurements with units and the manufacturer procedure used
Plan the scope
Use seasonal visits to cover heating and cooling operation. Do not force a mode or defrost test outside the manufacturer's permitted conditions. Record backup heat and dual-fuel controls separately from compressor heating.
A field documentation example
A cooling visit does not prove winter defrost or backup heat operation. Leave those tests Not recorded when they could not be performed, document why and specify the follow-up needed.
References and adaptation
For qualified HVAC professionals. Adapt to the equipment manual, approved scope and applicable requirements. These are original documentation aids, not manufacturer procedures, ACCA forms or compliance certificates. Use equipment-specific limits; no universal passing values are supplied.
Questions
Can I print a blank checklist without creating a report?
Yes. Download blank checklist PDF gives you an uncompleted field worksheet with room for results, notes and readings. It requires no account or visit details.
Can I edit the checklist and export a customer report?
Yes. Open Record a visit to use the shared service report builder. New report uses this page's checklist. You can edit items, add notes, measurements and photos, and export from Preview after recording the visit date and at least one result or observation. Unanswered items stay Not recorded.
Does opening this page replace my saved reports?
No. Existing reports stay in the shared library on this browser. Choose New report to start this checklist. Download a backup to preserve your reports or move them to another device; this free tool does not sync with operational Relay jobs.
Does a completed checklist certify safety or code compliance?
No. It records the work and observations entered by its author. Equipment procedures, qualified testing and applicable requirements determine acceptance. No readings or passing limits are filled in automatically.